Testing · Electrical

Breakers check boxInspection tunnel for modular circuit breakers

Electrical

Automatic in-line visual inspection system for 2-, 3- and 4-pole low-voltage modular circuit breakers, installed at the end of the production line.

6 s/pieceLine cycle time
13Checks
3Vision systems

Description

The tunnel performs 13 checks for component presence, correct type and possible visible defects.

The system includes three vision systems and a product conveyor. It is operated through a touch-panel HMI, with inspection results displayed in real time.

Technical specifications

Line cycle time6 s/piece
Checks13
Vision systems3
Types of checksPresence/absence, breakage and stains, screen printing/model correspondence and other checks
Operators required1 (30% of cycle time)
Product type2-, 3- and 4-pole low-voltage modular circuit breakers
InterfaceTouch-panel HMI
Electrical supply230 V · 50 Hz
Compressed air6 bar
Maximum power consumption3700 VA